<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>AUT Journal of Electrical Engineering</JournalTitle>
				<Issn>2588-2910</Issn>
				<Volume>45</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2013</Year>
					<Month>10</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Shielding Effectiveness of a Lossy Metallic Enclosure</ArticleTitle>
<VernacularTitle>Shielding Effectiveness of a Lossy Metallic Enclosure</VernacularTitle>
			<FirstPage>17</FirstPage>
			<LastPage>26</LastPage>
			<ELocationID EIdType="pii">425</ELocationID>
			
<ELocationID EIdType="doi">10.22060/eej.2013.425</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>M.</FirstName>
					<LastName>Pedram</LastName>
<Affiliation>MSc Student, Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>P.</FirstName>
					<LastName>Dehkhoda</LastName>
<Affiliation>Assistant Professor, Institute of Communications Technology and Applied Electromagnetics, Amirkabir University of Technology, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>H.</FirstName>
					<LastName>Sadeghi</LastName>
<Affiliation>Professor, Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>R.</FirstName>
					<LastName>Moini</LastName>
<Affiliation>Professor, Department of Electrical Engineering, Amirkabir University of Technology, Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2015</Year>
					<Month>10</Month>
					<Day>06</Day>
				</PubDate>
			</History>
		<Abstract>In this paper, shielding effectiveness (SE) of a perforated enclosure with imperfectly conducting walls is &lt;br /&gt;evaluated. To this end, first, an accurate numerical technique based on method of Moments (MoM) is&lt;br /&gt;presented. In this method, lossy metallic walls of the enclosure are replaced by equivalent electric surface&lt;br /&gt;current sources. Then, the impedance boundary condition on the imperfectly conducting surfaces is applied&lt;br /&gt;and an electric field integral equation is extracted. At the end, the integral equation is solved numerically by&lt;br /&gt;Galerkin method. In addition to the mentioned numerical method, an extremely fast analytical technique&lt;br /&gt;based on transmission line model(TLM) is proposed which is able to predict the SE with high level of&lt;br /&gt;accuracy over a large frequency bandwidth just in a few seconds.  For validation of both methods, other&lt;br /&gt;commercial softwares (FEKO and CST) are employed and several enclosures with different conductivities&lt;br /&gt;are studied. Lossy MoM method shows accurate results for conductivities down to 10S/m, while efficient&lt;br /&gt;TLM method proves its accuracy for conductivities down to 250S/m.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Finite Conductivity</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Lossy Metallic Box</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Shielding Effectiveness</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Shielding Enclosure</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Transmission Line Method</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://eej.aut.ac.ir/article_425_25b2822c2f5a3230abfadd476e8b04c9.pdf</ArchiveCopySource>
</Article>